Application  >  Tunnel Fire Protection  >  Lost shuttering (Single layer)  >  PROMATECT®-H
 
   
 
  Hong Kong Singapore Australia Malaysia India
 
Single layer -
Fixing with self-tapping screws as permanent formwork


With up to 240 minutes fire resistance

PROMATECT®-H
Areas of
application
Board
Thickness
FRL Fire Curve
Soffits 1 x 27mm* 120 minutes RWS
Soffits 1 x 25mm* 240 minutes Hydrocarbon
Walls 1 x 20mm* 240 minutes Hydrocarbon

* These are nominal protection thicknesses only. Actual thickness depends on a range of factors including concrete density, moisture content etc. Please consult Promat in all instances before specifying the product and thickness.

Ceiling System, Lost Formwork Method

The board thickness of the protection material is relevant to the strength of the concrete and the cover to the reinforcement. In some instances such as very high strength concrete, a greater thickness of protection material may be required.

This installation method is provided as a general guideline only. Please contact the Promat Technical Department for specific application requirements.

For more specific information concerning the fire protection of tunnels, please go to http://www.promat-tunnel.com/

Download full application details in PDF file. PDF download
 
 
 

Tunnel soffits/walls lost shuttering