email home
Application  >  Tunnel Fire Protection  >  Post cladding (Double layer)  >  PROMATECT®-H or PROMATECT®-T
 
   
 
  Hong Kong Singapore Australia Malaysia India
 
Double layer -
Fixing with anchor bolts


With up to 240 minutes fire resistance

PROMATECT®-H or PROMATECT®-T
Areas of
Application
Board
Tthickness
FRL Fire Curve
Soffits 1 x 15mm* &
1 x 27mm*
180 minutes RWS

* These are nominal protection thicknesses only. Actual thickness depends on a range of factors including concrete density, moisture content etc. Please consult Promat in all instances before specifying the product and thickness.

Post Construction Method

The board thickness of the protection material is relevant to the strength of the concrete and the cover to the reinforcement. In some instances such as very high strength concrete, a greater thickness of protection material may be required.

This installation method is provided as a general guideline only. Please contact the Promat Technical Department for specific application requirements.

For more specific information concerning the fire protection of tunnels, please go to http://www.promat-tunnel.com/

Download full application details in PDF file. PDF download
 
 
 

Tunnel soffits post cladding (Double layer)
Post cladding
Anchor bolts fixing


 
 
 
   © Copyright 2010 Promat International (Asia Pacific) Ltd. All rights reserved.