email home
Application  >  Partitions & External Walls  >  Steel Stud Partition  >  PROMINA®-60  >  Double Layer
 
   
 
  Hong Kong Singapore Malaysia India
 
Both sides - Horizontal Sheeting with gypsum board -
Fire attack from either side / Non-loadbearing


With up to 120 minutes fire resistance
Integrity & Insulation
  (Typical deflection details, movement joints)

PROMINA®-60
Board Thickness Stability
Rating
Integrity
Rating
Insulation
Rating
9mm - 120 minutes 120 minutes

For more architectural specification.
continue...

System Specification

Walls are to be constructed using PROMINA®-60 matrix engineered mineral boards all in accordance with the Architectural Specification in the manufacturer’s handbook. Relevant constructions are to be selected according to the required FRL of (-/120/120). All printed installation details are to be followed to ensure approval to BS476: Part 22 and AS1530: Part 4. All work to be certified by installer in an approved manner.


Download this full application detail on PDF version. PDF download

Steel stud partition   Horizontal Sheeting with gypsum board - Double layer    

Steel stud partition - Fire attack from either side / Non-loadbearing
Fire Rating
  FRL   -/120/120
  STANDARD   BS476: Part 22: 1987
AS1530: Part 4: 2005
  APPROVAL   PSB G41751/TSM
BRE CC89767B
Acoustic
  # STC
# R w
  46dB
45dB
  STANDARD   ISO140: Part 3: 1996
ISO717: Part 1: 1996
  PREDICTED
ASSESSMENT
  Marshall Day
18th October 2006
Construction
  MAXIMUM HEIGHT   7000mm
  MAXIMUM LENGTH   Unlimited
  PARTITION THICKNESS Nominal 113mm
  PARTITION MASS*   From 25.80kg/m²
# Margin of error is generally within ±3dB.  
*
Details for walls above 3000mm high are available on request.
 
 
 
 