email home
Application  >  Partitions & External Walls  >  Steel Stud Partition  >  PROMINA®-60  >  Double Layer
 
   
 
  Hong Kong Singapore Malaysia India
 
Both sides - Horizontal Sheeting with gypsum board -
Fire attack from either side / Non-loadbearing


With up to 120 minutes fire resistance
Integrity & Insulation
  (Typical deflection details, movement joints)

PROMINA®-60
Board Thickness Stability
Rating
Integrity
Rating
Insulation
Rating
9mm - 120 minutes 120 minutes

For more architectural specifications,
continue...

System Specification

Walls are to be constructed using PROMINA®-60 matrix engineered mineral boards all in accordance with the Architectural Specification in the manufacturer’s handbook. Relevant constructions are to be selected according to the required FRL of (-/120/120). All printed installation details are to be followed to ensure approval to BS476: Part 22 and AS1530: Part 4. All work to be certified by installer in an approved manner.


Download full application details in PDF file. PDF download

Steel stud partition   Horizontal Sheeting with gypsum board - Double layer    

Steel stud partition - Fire attack from either side / Non-loadbearing
Fire Rating
  FRL   -/120/120
  STANDARD   BS476: Part 22: 1987
AS1530: Part 4: 2005
  APPROVAL   PSB G41751/TSM
BRE CC89767B
Acoustic
  # STC
# R w
  46dB
45dB
  STANDARD   ISO140: Part 3: 1996
ISO717: Part 1: 1996
  PREDICTED
ASSESSMENT
  Marshall Day
18th October 2006
Construction
  MAXIMUM HEIGHT   7000mm
  MAXIMUM LENGTH   Unlimited
  PARTITION THICKNESS Nominal 113mm
  PARTITION MASS*   From 25.80kg/m²
# Margin of error is generally within ±3dB.  
*
Details for walls above 3000mm high are available on request.
 
 
 
 
   © Copyright 2010 Promat International (Asia Pacific) Ltd. All rights reserved.