Both sides - Horizontal sheeting (Single layer) -
Fire attack from either side / Non-loadbearing
| PROMINA®-60 |
| Board Thickness |
Stability Rating |
Integrity Rating |
Insulation Rating |
| 9mm |
- |
60 minutes |
60 minutes |
| 9mm |
- |
120 minutes |
60 minutes |
For more architectural specifications, continue...
|
|
 |
 |
 |
|
System Specification
Walls are to be constructed using PROMINA®-60 matrix engineered mineral boards all
in accordance with the Architectural Specification in the manufacturer’s handbook. Relevant constructions are to be selected according to the
required FRL of (-/60/60) and (-/120/60) of the selected elements. All printed installation details are to be followed to ensure approval to
BS476: Part 22 and AS1530: Part 4. All work to be certified by installer in an approved manner.
|
Download full application details in PDF file. |
 |
|
|