Both sides - Vertical sheeting with strip joint -
Fire attack from either side / Non-loadbearing
 |
With up to 60minutes & 120 minutes fire resistance |
 |
Integrity & Insulation |
| PROMINA®-60 |
| Board Thickness |
Stability Rating |
Integrity Rating |
Insulation Rating |
| 9mm |
- |
60 minutes |
60 minutes |
| 9mm |
- |
120 minutes |
120 minutes |
For more architectural specification. continue...
|
|
 |
 |
 |
|
System Specification
Walls are to be constructed using PROMINA®-60
matrix engineered mineral boards all in accordance with the Architectural Specification in the manufacturer’
s handbook. Relevant constructions are to be selected according to the required FRL of (-/60/60) and
(-/120/120). All printed installation details are to be followed to ensure approval to BS476: Part 22.
All work to be certified by installer in an approved manner.
|
Download this full application detail