PROMATECT®-H
Board Thickness Stability
Rating
Integrity
Rating
Insulation
Rating
6mm - 30 minutes 30 minutes
9mm - 60 minutes 60 minutes
9mm - 90 minutes 90 minutes
9mm - 120 minutes 120 minutes

For more architectural specification.
continue...

System Specification

Walls are to be constructed using PROMATECT®-H matrix engineered mineral boards all in accordance with the Architectural Specification in the manufacturer’s handbook. Relevant constructions are to be selected according to the required FRL of (.../.../...). All printed installation details are to be followed to ensure approval to BS476: Part 22 and AS1530: Part 4. All work to be certified by installer in an approved manner.





Download this full application detail on PDF version. PDF download

Timber stud partition   Vertical sheeting - Single layer    

Timber stud partition - Fire attack from either side / Non-loadbearing
Fire Rating
  FRL   -30/30
-/60/60
-/90/90
-/120/120
  STANDARD   BS476: Part 22: 1987
AS1530: Part 4: 2005
  APPROVAL   WFRA 45713
Acoustic
  # STC



# R w
  36dB (for -/30/30)
39dB (for -/60/60)
39dB (for -/90/90)
39dB (for -/120/120)

35dB (for -/30/30)
39dB (for -/60/60)
39dB (for -/90/90)
39dB (for -/120/120)
  STANDARD   ISO140: Part 3: 1996
ISO717: Part 1: 1996
  PREDICTED
ASSESSMENT
  Marshall Day
18th October 2006
Construction
  MAXIMUM HEIGHT   3000mm
  MAXIMUM LENGTH   Unlimited
  PARTITION THICKNESS Nominal 75mm (for -/30/30)
Nominal 81mm (for -/60/60)
Nominal 81mm (for -/90/90)
Nominal 81mm (for -/120/120)
  PARTITION MASS*   From 20.95kg/m² (for -/30/30)
From 27.65kg/m² (for -/60/60)
From 29.41kg/m² (for -/90/90)
From 31.89kg/m² (for -/120/120)
# Margin of error is generally within ±3dB.  
*
Details for walls above 3000mm high are available on request.
 
 
 
 