email home
Application  >  Partitions & External Walls  >  Timber Stud Partition  >  PROMATECT®-100  >  Both Sides (Single layer)
 
   
 
  Hong Kong Singapore Australia Malaysia India
 
Both sides - Vertical sheeting (Single layer) -
Fire attack from either side /
Non-loadbearing and Loadbearing


With up to 120 minutes fire resistance
Integrity & Insulation
  (Movement joints & junction details)

PROMATECT®-100
Board Thickness Stability
Rating
Integrity
Rating
Insulation
Rating
20mm - 120 minutes 120 minutes
20mm 120 minutes 120 minutes 120 minutes

For more architectural specification.
continue...

System Specification

Walls are to be constructed using PROMATECT®-100 matrix engineered mineral boards all in accordance with the Architectural Specification in the manufacturer’s handbook. Relevant constructions are to be selected according to the required FRL of (.../.../...). All printed installation details are to be followed to ensure approval to BS476: Part 22 and AS1530: Part 4. All work to be certified by installer in an approved manner.




Download this full application detail on PDF version. PDF download

Timber stud partition   Vertical sheeting - Non-loadbearing   Horizontal sheeting with nogging joint - Loadbearing  

Timber stud partition - Fire attack from either side / Non-loadbearing & Loadbearing
Fire Rating
  FRL   -/120/120
120/120/120
  STANDARD   BS476: Part 22: 1987
AS1530: Part 4: 2005
  APPROVAL   BRE CC232158A
BRE CC232158B
Acoustic
  # STC
# R w
  35dB
39dB (-4)
  STANDARD   ISO140: Part 3: 1996
ISO717: Part 1: 1996
  PREDICTED
ASSESSMENT
  Marshall Day
18th October 2006
Construction
  MAXIMUM HEIGHT*   3000mm
  MAXIMUM LENGTH   Unlimited
  PARTITION THICKNESS From 130mm
  PARTITION MASS   From 37kg/m²
# Margin of error is generally within ±3dB.  
*
Details for walls above 3000mm high are available on request.
 
 
 
 