112 Results
120min PROMATECT®-H cladding to steel ducts ≤ 1500mm Width (without Cover Strips) 5
  • Fire resistance level (integrity) (E) :

    120min


  • Fire resistance level (insulation) (I) :

    120min


  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) :

    120min


  • Fire exposure : internal
  • Product thickness :

    15mm, with mineral wool: 30mm x 100kg/m3


  • Maximum duct closure width :

    1500mm


120min PROMATECT®-H cladding to steel ducts ≤ 1500mm Width (without Cover Strips) 4
  • Fire resistance level (integrity) (E) : 120 min
  • Fire resistance level (insulation) (I) : 120 min
  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) : 120 min
  • Fire exposure : internal
  • Product thickness : 12 mm, with mineral wool: 2 x 25mm x 100kg/m3
  • Maximum duct closure width : 1500 mm
240min PROMATECT®-H cladding to steel ducts greater than 1500mm Width 3
  • Fire resistance level (integrity) (E) : 240 min
  • Fire resistance level (insulation) (I) : 30 min
  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) : 240 min
  • Fire exposure : internal and external
  • Product thickness : 20 mm, no mineral wool required
  • Maximum duct closure width : 6000 mm
120min PROMATECT®-H cladding to steel ducts ≤ 1500mm Width (without Cover Strips) 3
  • Fire resistance level (integrity) (E) : 120 min
  • Fire resistance level (insulation) (I) : 60 min
  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) : 120 min
  • Fire exposure : internal
  • Product thickness : 12 mm, with mineral wool: 25mm x 60kg/m3
  • Maximum duct closure width : 1500 mm
120min PROMATECT®-H cladding to steel ducts ≤ 1500mm Width (without Cover Strips) 1
  • Fire resistance level (integrity) (E) : 120 min
  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) : 120 min
  • Fire exposure : internal
  • Product thickness : 9 mm, no mineral wool required
  • Maximum duct closure width : 1500 mm
240min PROMATECT®-H cladding to steel ducts ≤ 1500mm Width 4
  • Fire resistance level (integrity) (E) : 240 min
  • Fire resistance level (insulation) (I) : 60 min
  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) : 240 min
  • Fire exposure : internal and external
  • Product thickness : 12 mm, with mineral wool: 50mm x 100kg/m3
  • Maximum duct closure width : 1500 mm
240min PROMATECT®-H cladding to steel ducts ≤ 1500mm Width (without Cover Strips) 2
  • Fire resistance level (integrity) (E) : 240 min
  • Fire resistance level (insulation) (I) : 240 min
  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) : 240 min
  • Fire exposure : internal and external
  • Product thickness : 25 mm, with mineral wool: 2 x 50mm x 100kg/m3
  • Maximum duct closure width : 1500 mm
240min PROMATECT®-H cladding to steel ducts greater than 1500mm Width 4
  • Fire resistance level (integrity) (E) : 240 min
  • Fire resistance level (insulation) (I) : 60 min
  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) : 240 min
  • Fire exposure : internal and external
  • Product thickness : 12 mm, with mineral wool: 50mm x 100kg/m3
  • Maximum duct closure width : 6000 mm
240min PROMATECT®-H cladding to steel ducts greater than 1500mm Width 7
  • Fire resistance level (integrity) (E) : 240 min
  • Fire resistance level (insulation) (I) : 240 min
  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) : 240 min
  • Fire exposure : internal and external
  • Product thickness : 25 mm, with mineral wool: 2 x 25mm x 100kg/m3
  • Maximum duct closure width : 6000 mm
120min PROMATECT®-H cladding to steel ducts ≤ 1500mm Width 4
  • Fire resistance level (integrity) (E) : 120 min
  • Fire resistance level (insulation) (I) : 120 min
  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) : 120 min
  • Fire exposure : internal and external
  • Product thickness : 9 mm, with mineral wool: 100mm x 100kg/m3
  • Maximum duct closure width : 1500 mm
120min PROMATECT®-H cladding to steel ducts greater than 1500mm Width 1
  • Fire resistance level (integrity) (E) : 120 min
  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) : 120 min
  • Fire exposure : internal and external
  • Product thickness : 9 mm, no mineral wool required
  • Maximum duct closure width : 6000 mm
120min PROMATECT®-H cladding to steel ducts greater than 1500mm Width 8
  • Fire resistance level (integrity) (E) :

    120min


  • Fire resistance level (insulation) (I) :

    120min


  • Fire resistance level (Load Bearing Capacity / Structural adequacy in minutes) (R) :

    120min


  • Fire exposure : external
  • Product thickness :

    15mm, with mineral wool: 2 x 25mm x 100kg/m3


  • Maximum duct closure width :

    6000mm