PromatMultiSeal® Cast-in Collar is designed to be fixed to the formwork prior to pouring concrete floor slabs to provide openings in floor slabs for multiple service penetrations.

Promat MultiSeal® Cast-in Collar is available in THREE (3) sizes:
  1. Small, for services up to nominal 75mm diameter;
  2. Medium, for services up to nominal 120mm diameter; and
  3. Large, for services up to nominal 170mm diameter.

Promat MultiSeal® Cast-in collars are designed to provide openings in cast slabs. The product will not provide a seal in the event of a fire and has no fire resistance level classification.

Dimension
< #Back#

DIMENSION

Code no.   MSS MSM MSL
Maximum diameter of services mm 75* 120* 170
Body H mm 250 250 250
D1 mm 95 140 190
Flange D2 mm 155 198 253
* Allowance of 10mm for backfill around services

 

Promat MultiSeal® Cast-in Collars are manufactured under a quality management system certified in accordance with ISO 9001: 2008. The production unit has passed the site audit of ISO 14001 and all manufacturing processes are in accordance with the environmental standards of ISO 14001: 2004 and the safety standards of AS 4801: 2001.

DIMENSION

Code no.   MSS MSM MSL
Maximum diameter of services mm 75* 120* 170
Body H mm 250 250 250
D1 mm 95 140 190
Flange D2 mm 155 198 253
* Allowance of 10mm for backfill around services

 

Promat MultiSeal® Cast-in Collars are manufactured under a quality management system certified in accordance with ISO 9001: 2008. The production unit has passed the site audit of ISO 14001 and all manufacturing processes are in accordance with the environmental standards of ISO 14001: 2004 and the safety standards of AS 4801: 2001.

Health & Safety
< #Back#

HEALTH & SAFETY

No special precautions are required. However, to avoid potential for fibre generation exists, please wear appropriate personal protection gear (safety goggles, protective clothing and dust mask). For more information please check the material safety data sheet, available upon request.

 

WASTE DISPOSAL

Handle as construction industry waste and dispose of in compliance with all local and national regulations in the appropriate and approved manner.

HEALTH & SAFETY

No special precautions are required. However, to avoid potential for fibre generation exists, please wear appropriate personal protection gear (safety goggles, protective clothing and dust mask). For more information please check the material safety data sheet, available upon request.

 

WASTE DISPOSAL

Handle as construction industry waste and dispose of in compliance with all local and national regulations in the appropriate and approved manner.