PROMASEAL® Wall Collars

ADVANTAGES

Fire Resistant Collar for Plastic Pipes Penetration Seals

PROMASEAL® Wall Collar is designed for insertion into wall elements made of matrix engineered mineral, Cement Bound Matrix, PromaX® mineral, calcium silicate, fibre silicate, plasterboard, concrete or masonry, and has been tested on uPVC and HDPE pipes.

Similar to the PROMASEAL® Retrofit Collar, this is a split type collar enabling retro fitting where necessary.

Dimension
< #Back#

DIMENSION

Code no.     FCW 40 FCW 50 FCW 65 FCW 100 FCW 150
Pipe nominal diameter   mm 40 50 65 100 150
Body H mm 120 120 120 120 120
D1 mm 80* 90* 107* 153* 203*
D2 mm 47 60 75 116 164
* Additional allowance of 3mm for clip

 

PROMASEAL® Wall Collar are manufactured under a quality management system certified in accordance with ISO 9001: 2008. The production unit has passed the site audit of ISO 14001 and all manufacturing processes are in accordance with the environmental standards of ISO 14001: 2004 and the safety standards of AS 4801: 2001.

DIMENSION

Code no.     FCW 40 FCW 50 FCW 65 FCW 100 FCW 150
Pipe nominal diameter   mm 40 50 65 100 150
Body H mm 120 120 120 120 120
D1 mm 80* 90* 107* 153* 203*
D2 mm 47 60 75 116 164
* Additional allowance of 3mm for clip

 

PROMASEAL® Wall Collar are manufactured under a quality management system certified in accordance with ISO 9001: 2008. The production unit has passed the site audit of ISO 14001 and all manufacturing processes are in accordance with the environmental standards of ISO 14001: 2004 and the safety standards of AS 4801: 2001.

Health & Safety
< #Back#

HEALTH & SAFETY

No special precautions are required. However, to avoid potential for fibre generation exists, please wear appropriate personal protection gear (safety goggles, protective clothing and dust mask). For more information please check the material safety data sheet, available upon request.

 

WASTE DISPOSAL

Handle as construction industry waste and dispose of in compliance with all local and national regulations in the appropriate and approved manner.

HEALTH & SAFETY

No special precautions are required. However, to avoid potential for fibre generation exists, please wear appropriate personal protection gear (safety goggles, protective clothing and dust mask). For more information please check the material safety data sheet, available upon request.

 

WASTE DISPOSAL

Handle as construction industry waste and dispose of in compliance with all local and national regulations in the appropriate and approved manner.