From Above Type 2 -
Fire attack from below / Loadbearing


With up to 60 minutes fire resistance
Integrity & Insulation
Please consult Promat for ceiling spans details
  (Perimeter details)

PROMATECT®-H
Board Thickness Stability
Rating
Integrity
Rating
Insulation
Rating
12mm 60 minutes 60 minutes 60 minutes

Please contact Promat for Architectural Specification to meet specific performance requirements.

System Specification

Suspended ceilings are to be constructed using PROMATECT®-H matrix engineered mineral boards all in accordance with the Architectural Specification in the manufacturer’s handbook. Relevant constructions are to be selected according to the required FRL 60/60/60 minutes of the selected elements. All printed installation details are to be followed to ensure approval to BS476: Part 22. All work to be certified by installer in an approved manner.

Download full application details in PDF file. PDF download

From Above Type 2   Fixing details    

From Above Type 2 - Fire attack from below
Fire Rating
  FRL   60/60/60
  STANDARD   BS476: Part 21: 1987
  APPROVAL   WARRES 36910
BRE letter (27th Jul 1987)
Acoustic
  # STC
# R w
  Fro acoustic rating,
please consult Promat.
  STANDARD   ISO140: Part 3: 1996
ISO717: Part 1: 1996
  PREDICTED
ASSESSMENT
 
Construction
  CEILING THICKNESS   264mm
  CEILING MASS   From 18.5kg/m²
# Margin of error is generally within ±3dB.  
 
 
 