Type 5 -
Fire attack from below / Loadbearing


With up to 120 minutes fire resistance
Integrity & Insulation
Please consult Promat for ceiling spans details
  (Perimeter details)

PROMATECT®-H
Board Thickness Stability
Rating
Integrity
Rating
Insulation
Rating
2 x 15mm 120 minutes 120 minutes 120 minutes

For more architectural specifications,
continue...

System Specification

Ceilings for timber floor protection are to be constructed using PROMATECT®-H matrix engineered mineral boards all in accordance with the Architectural Specification in the manufacturer’s handbook. Relevant constructions are to be selected according to the required FRL 120/120/120 minutes of the selected elements. All printed installation details are to be followed to ensure approval to BS476: Part 21. All work to be certified by installer in an approved manner.

Download full application details in PDF file. PDF download

Type 5   Fixing details    

Type 5 - Fire attack from below
Fire Rating
  FRL   120/120/120
  STANDARD   BS476: Part 21: 1987
  APPROVAL   WARRES 48333
Acoustic
  # STC
# R w
  45dB
45dB
  STANDARD   ISO140: Part 3: 1996
ISO717: Part 1: 1996
  PREDICTED
ASSESSMENT
  Marshall Day
17th August 2007
Construction
  CEILING THICKNESS   274mm
  CEILING MASS   From 31.2kg/m²
# Margin of error is generally within ±3dB.  
 
 
 