email home
Application  >  Ceilings & Floors  >  Self-supporting Ceiling Membrane  >  PROMATECT®-H  >  Type 2 (Option a & b)
 
   
 
  Hong Kong Singapore Australia Malaysia India
 
Type 2 (Option a & Option b) -
Fire attack from above and below / Non-loadbearing


With up to 240 minutes fire resistance
Integrity & Insulation
Ceiling spans from 3000mm to 6000mm
  (Perimeter details & control joints)

PROMATECT®-H
Board Thickness Stability
Rating
Integrity
Rating
Insulation
Rating
2 x 12mm - 240 minutes 240 minutes

For more architectural specification.
continue...

System Specification

Self-supporting ceiling membrane systems are to be constructed using PROMATECT®-H matrix engineered mineral boards all in accordance with the Architectural Specification in the manufacturer’s handbook. Relevant constructions are to be selected according to the required FRL -/240/240 minutes of the selected elements. All printed installation details are to be followed to ensure approval to BS476: Part 22 or AS1530: Part 4. All work to be certified by installer in an approved manner.

Download this full application detail on PDF version. PDF download

Type 2 (Option a)   Option a - fixing details   Type 2 (Option b)   Option b - fixing details


Type 2 (option a) - Fire attack from above & below
Fire Rating
  FRL   -/240/240
  STANDARD   BS476: Part 22: 1987
AS1530: Part 4: 2005
  APPROVAL   CSIRO FSH1126
WARRES 58350
BRE CC84094

Acoustic
  # STC
# R w
  From 56dB to 59dB
From 57dB to 60dB
  STANDARD   ISO140: Part 3: 1996
ISO717: Part 1: 1996
  PREDICTED
ASSESSMENT
  Marshall Day
16th August 2007

Construction
  CEILING THICKNESS   From 148mm
  CEILING MASS   From 69.5kg/m³

#

Margin of error is generally within ±3dB.

 
 
 
 
   © Copyright 2008 Promat International (Asia Pacific) Ltd. All Right Reserved.