Concealed Grip Type (Suspended Ceiling Membrane) -
Fire attack from below / Loadbearing


With up to 120 minutes fire resistance
Integrity & Insulation
Please consult Promat for ceiling spans details
  (Perimeter details & control joints)

PROMATECT®-H
Board Thickness Stability
Rating
Integrity
Rating
Insulation
Rating
12mm 120 minutes 120 minutes 120 minutes

For more architectural specification.
continue...

System Specification

Suspended ceiling systems are to be constructed using PROMATECT®-H matrix engineered mineral boards all in accordance with the Architectural Specification in the manufacturer’s handbook. Relevant constructions are to be selected according to the required FRL 120/120/120 minutes of the selected elements. All printed installation details are to be followed to ensure approval to BS476: Part 22. All work to be certified by installer in an approved manner.

Download this full application detail on PDF version. PDF download

Concealed Grip Type   Fixing details    


Concealed Grip Type - Fire attack from below
Fire Rating
  FRL   120/120/120
  STANDARD   BS476: Part 23: 1987
  APPROVAL   FIRTO TE5763
BRE CC81584B

Acoustic
  # STC
# R w
  29dB
29dB
  STANDARD   ISO140: Part 3: 1996
ISO717: Part 1: 1996
  PREDICTED
ASSESSMENT
  Marshall Day
16th August 2007

Construction
  CEILING THICKNESS   62mm
  CEILING MASS   From 14.6kg/m³

#

Margin of error is generally within ±3dB.

 
 
 
 